LUVANO

Combining a wood-burning boiler stove and a heat pump

When wood is burning, your heat pump takes a break.

When wood is burning, the LUVANO® supplies the heat – in the transitional season as well as on cold days. If heat is lacking, your heat pump steps in automatically.

Why you opt for a heat pump

In autumn 2022 the energy advice service of the Verbraucherzentrale (consumer advice centre) reported: “Stoves have been sold out in DIY stores for weeks.” At the time, many people were looking for a way not to depend on gas alone in winter. Some bought a wood stove, others planned a heat pump. Behind both decisions lies the same thought.

Surveys still show this today. People who own or are planning a heat pump name independence from oil and gas prices as the first reason (60 per cent), followed by lower heating costs (57 per cent) and climate protection (44 per cent). The trigger is usually the old heating system: for 58 per cent of those planning a heat pump, it is the failure of the boiler. And 58 per cent of those who run a wood stove say it makes them independent of imported oil and gas, because firewood is available locally.

The heat pump and the wood fire therefore solve the same problem in two ways. One uses electricity and ambient heat, the other a fuel from the region.

With a heat pump, however, the dependency shifts: away from oil and gas, towards electricity. As early as 2022, the Verbraucherzentrale cited the concern that central heating systems depend on electricity as a reason for the sold-out stoves. Wood provides a counterweight – a second energy source that you stock yourself and that does not come from the power grid. That is a degree of self-sufficiency that many people consciously seek today. There is a simple solution for a power cut too – talk to us.

A LUVANO® in front of a natural stone wall.
A LUVANO® in front of a natural stone wall.

Funding: what is funded for a heat pump and a boiler stove

For many, funding is the reason to install the heat pump now: among homeowners who chose a heat pump when replacing their heating, 72 per cent named the funding as a reason. It is funded through the heating subsidy of the KfW (German state development bank) (programme 458) with basic funding and bonuses. Part of this will be reduced gradually from 2027; what counts is the situation when you apply. With a heat pump you also meet the requirements of the Gebäudemodernisierungsgesetz (GModG, German Building Modernisation Act).

If you are installing a heat pump anyway, the shared buffer tank is part of the new heating system. As an associated measure, it can be co-funded through the KfW heating subsidy. The LUVANO® itself is not eligible for funding – but the step towards it becomes smaller.

→ Funding

The cold day: when a boiler stove takes the load off the heat pump

The most common concern about heat pumps is not the price but the cold: depending on the group, 31 to 42 per cent of owners fear the heat pump might not get the house warm enough on cold days. Around a third cannot judge at all whether their own house is suitable.

How justified this concern is can be seen from a measurement by Fraunhofer ISE on 77 heat pumps in occupied existing houses. Air-to-water heat pumps there achieved an average seasonal performance factor of 3.4, i.e. 3.4 kilowatt hours of heat per kilowatt hour of electricity, with a range of 2.6 to 4.9. And then the decisive sentence: “Correlations between efficiency and the various factors influencing efficiency were found only with the heating circuit temperatures.”

What this actually says: it is not the year of construction that determines how well a heat pump works, nor insulation alone. What matters is how warm the heating water has to be for the house to get warm – the flow temperature. According to the Verbraucherzentrale, each degree less brings about 2 to 3 per cent more efficiency. The flow temperature is highest on the coldest days. That is exactly when the house needs the most heat, and exactly when the heat pump produces each kilowatt hour with the most electricity.

There is even a technical term for this. The EU Ecodesign Regulation calls it the bivalent temperature: the outdoor temperature “below which the declared capacity requires supplementary heater capacity”. Another reading makes it easier to understand: every heat pump is designed for a point below which it needs support. That is not a flaw but part of the planning – the only question is where this support comes from. Experts call a system with two heat sources bivalent.

Let us imagine a house from the 1970s, partly renovated, with radiators and an air-to-water heat pump. It is January, minus eight degrees outside, and the heating curve raises the flow temperature. In the afternoon the family puts wood into the LUVANO® in the living room. It transfers up to 85 per cent of its output to the heating water to supply the radiators and the hot water preparation. As long as the LUVANO® is burning or the tank is charged, the TOUCH control holds the heat pump back. At night the fire is out, and the tank continues to keep the heat available. Only when energy is needed does the heat pump step in again.

Whether the tank gets charged and how long it is enough to supply the building depends on the ratio between the heat demand of the house and the water-side output of the stove – a figure for this exists only for the individual house. What the LUVANO® makes possible is shown by feedback from our customers: some heat with 5 stacked cubic metres of wood a year, others with 15 and more. How much heat you obtain from wood is up to you.

This is how much energy is in wood

5 stacked cubic metres of wood
8,000kWh
New build, 150m², one year
9,000kWh
older detached house, one year
20,000kWh
15 stacked cubic metres of wood
24,000kWh

1 stacked cubic metre of mixed wood, half beech and half spruce, air-dried: around 1,600kWh. Sources: Bayerische Landesanstalt für Wald und Forstwirtschaft (Bavarian State Institute of Forestry), Merkblatt 12 (information sheet 12) (2024); Verbraucherzentrale (2026).

→ Can a stove replace the heating system?

The fact that the living room does not overheat is due to the ratio of room output to total output. With many boiler stoves, a considerable part of the output remains in the room where the stove is installed. The LUVANO® is built as a boiler with a viewing window and transfers just under 15 per cent of its output to the room. That is why you can run it for a long time on a cold day – and equally in the transitional season, from September into May, when the living room hardly needs any heat but the bathroom does.

(Heat pumps are an efficient solution when the building is properly prepared. A boiler stove can, however, relieve them perfectly – especially if there is already a wish for a real fire, romance and more independence.)

Can the heat pump be smaller with a boiler stove?

We often hear this question when a boiler stove is to help with the heating. The answer is usually no. There will be days when nobody adds wood – on holiday, for example. On those days the heat pump carries the entire heating load. The heating installer therefore sizes its output according to the heat demand of the house, as before.

Another aspect is the investment itself. With your heating you create a concept for many years and decades. During this time, circumstances and needs can change. That is why you should not make yourself dependent on your heating system through a special design – after all, this also benefits the value of your property.

It can, however, be simpler, for two reasons. Firstly, it works with a large buffer tank that allows it longer running times. Secondly, the share of heat it has to produce with electricity decreases, because on wood days the LUVANO® delivers part of it to the tank. This also means it matters less if the heat pump achieves a somewhat lower seasonal performance factor: the smaller its share of the heating work, the less your electricity costs depend on its efficiency.

How the stove and heat pump work together via the buffer tank

The LUVANO® boiler stove and your heat pump share one buffer tank. It is the connecting component: the LUVANO® charges it with heat from wood, the heat pump with heat from electricity and ambient air, and the heating circuits draw the heat from it, regardless of where it comes from. As long as your LUVANO® is burning or the buffer tank is charged, the TOUCH control holds the heat pump back when it is not needed. And if you deliberately want to heat with wood only, you lock it out at the touch of a button.

One technical question almost always comes up: do the temperatures match? The LUVANO® is integrated like a boiler and works with hot water; its return temperature control keeps the water flowing back to it above 60°C. A heat pump, on the other hand, works more economically the lower the temperature it has to produce.

That is why the two meet not in the pipework but in the buffer tank. Its stratification device keeps the hot water at the top and the cooler water below, and via its mixing valve the heating circuit receives only the temperature it needs. As long as the wood fire keeps the tank charged, the heat pump stays off. It only steps in once the tank has cooled down, and then works at its own, lower temperature level. Correctly integrated, the stove therefore does not interfere with the heat pump.

For the LUVANO® we recommend a buffer volume of at least 500 litres, ideally 800 to 1,000 litres. → Buffer tank

additional Heat sources: Your heat pump Hot water heating Heating circuit (radiators) Pump Pump Buffer tank Thermostatic valve Mixing valve
This is how the LUVANO® and a heat pump are integrated: the LUVANO® charges the buffer tank via a pump and thermal valve, and the heat pump feeds in via its own pump. The hot water preparation and the heating circuit with pump and mixing valve are supplied from the tank. Schematic diagram. Different hydraulic configurations are available depending on requirements.

Also with a heat pump from another manufacturer

The concept does not depend on a particular make. A heat pump from another manufacturer can, as a rule, also be integrated via the shared buffer tank. We are happy to provide you and your heating engineer with suitable hydraulic diagrams and proposals for integration. You will find more precise details in the planning documents. → Request planning documents If the heat pump is still at the planning stage, we can supply everything from a single source on request: heat pump, buffer tank, hydraulics and control technology.

Heat pump with a boiler stove in older buildings, renovated houses and new builds

In an unrenovated older building with small radiators, the heat pump needs high flow temperatures on cold days. Many owners therefore believe the whole house must be renovated first. However, the Fraunhofer ISE measurement found no link between building age and efficiency; sufficiently large radiators worked about as well as surface heating. So whether your house is suitable can be checked rather than guessed. Here the LUVANO® helps where the heat pump has to work hardest.

In a renovated existing building, the heating surfaces are what count: if radiators or surface heating are suitably sized, the flow temperature falls and the heat pump works more economically – that is the connection from the section “The cold day”. At the same time, the heat demand of the house falls, and the LUVANO® can take on an even larger share of it – in the transitional season as well as on the evenings when you like to light a fire anyway.

In a new build the heating load is small. What matters then is how much heat a stove releases into the room. At just under 15 per cent, overheating of the room where the stove is installed is significantly reduced. If required, the LUVANO® also operates room-sealed in accordance with EN 16510 and therefore also suits a building with a ventilation system. → The LUVANO® in a new build

→ Do you still heat with oil or gas today? Supplementing oil or gas heating with a boiler stove

In brief

A boiler stove and a heat pump complement each other via a shared buffer tank. The LUVANO® transfers most of its heat to the heating water and, if you wish, can completely replace the heat pump in the transitional season and significantly relieve it on very cold days. This does not make the heat pump smaller, but simpler, because the large tank allows it longer running times. The buffer tank can be co-funded as part of a new heat pump system; the LUVANO® itself cannot.

A LUVANO® in a living space.
A LUVANO® in a living space.

Frequently asked questions

Is the LUVANO® compatible with my heat pump?

As a rule, yes, even if it comes from another manufacturer. We are happy to provide your heating engineer with suitable hydraulic diagrams. → Integration

Does the stove affect the efficiency of the heat pump?

Not if it is correctly integrated. The two meet in the buffer tank, not in the pipework. As long as the wood fire keeps the tank charged, the TOUCH control holds the heat pump back; after that it works at its own, lower temperature level. → How the two work together

How large does the buffer tank for a stove and heat pump need to be?

For the LUVANO®, at least 500 litres, ideally 800 to 1,000 litres. The larger the tank, the more heat from one load of fuel it takes up and the longer the heat pump can pause. → Buffer tank

Does it pay off?

That depends on the heat demand of your house, on your heat pump and on how often you light the stove. We therefore do not give a flat figure – we are happy to discuss it with you: +49 9129 90943-0.

What happens in a power cut?

There is a simple solution for a power cut too – talk to us: +49 9129 90943-0.

Is there funding for the LUVANO®?

The LUVANO® itself is not eligible for funding. If you install a heat pump at the same time, the shared buffer tank can be co-funded through the KfW heating subsidy – provided the funding has been applied for before anything is commissioned.

Does the LUVANO® have to undergo recurring emission tests?

In principle, the LUVANO® is a boiler stove in accordance with EN 16510 (previously EN 13240). Whether it has to be tested on a recurring basis nevertheless depends on certain circumstances. → Emission testing obligation

Sources12 references – click to expand
  • Verbraucherzentrale: “So viel teurer macht der CO₂-Preis Ihre Heizkosten”, as of 06.01.2026 (typical consumption of an older detached house) – verbraucherzentrale.de
  • Bayerische Landesanstalt für Wald und Forstwirtschaft (LWF, Bavarian State Institute of Forestry): information sheet 12 “Der Energieinhalt von Holz”, November 2024, pp. 1 and 3 – lwf.bayern.de
  • Fraunhofer ISE: final report “WP-QS im Bestand”, 2nd version of 25.11.2025, pp. 7 and 77 – ise.fraunhofer.de
  • Verbraucherzentrale Rheinland-Pfalz: Faktencheck Wärmepumpe (heat pump fact check), 10.02.2026 – verbraucherzentrale-rlp.de
  • Regulation (EU) No 813/2013 (ecodesign for space heaters), Annex I point 39 – eur-lex.europa.eu
  • Institut für Demoskopie Allensbach on behalf of the Initiative Klimaneutrales Deutschland: survey of owner-occupiers, August 2025 – klimareporter.de
  • Öko-Institut, ifeu, co2online: Working Paper “Wärmepumpen im Gebäudebestand”, 07.10.2026 – oeko.de
  • forsa on behalf of the Bundesverband Wärmepumpe (German Heat Pump Association): experiences of heat pump owners, March 2025 – haustec.de
  • Umweltbundesamt: evaluation report “Heizen mit Holzöfen” (survey April 2021) – umweltbundesamt.de
  • Verbraucherzentrale Bundesverband, energy advice: press release of 27.10.2022 – verbraucherzentrale-energieberatung.de
  • KfW: heating subsidy for private individuals (458) and technical FAQ BEG EM, version 8.0, no. 8.34 – kfw.de
  • Bundesregierung (German Federal Government): Das neue Gebäudemodernisierungsgesetz – bundesregierung.de