LUVANO

Planning the LUVANO®: chimney, positioning, buffer tank

Everything is clarified in advance.

A boiler stove works differently from a classic wood stove: it transfers only part of its heat directly to the room where it is installed, and the rest to the heating water, which carries it into the buffer tank. The design determines the ratio: with the LUVANO®, a boiler with a viewing window, up to 85% of the output goes into the heating water and just under 15% into the room. For the system to work reliably and comfortably, stove output, buffer tank, hydraulics, chimney, combustion air and control technology should be coordinated with each other at an early stage. We check your chimney free of charge, give planning advice on positioning, buffer tank and integration, and coordinate with your heating installer.

LUVANO®Buffer tankRadiatorsUnderfloor heatingHot water
First into the buffer tank, then into distribution: the tank keeps the heat ready for radiators, underfloor heating and hot water.

How it works

1 Information request 2 Basic data entry 3 Chimney check 4 Chimney sweep 5 Planning 6 Installation 7 Put into operation
Seven steps – from the information pack to commissioning.
  1. Request information. You receive the brochure, price list, planning documents and the form for the free chimney check.
  2. Record the basic data. You decide on the possible location of the LUVANO® and check whether there is space for the buffer tank and technical equipment, if these are not yet in place. The routing of the lines between the stove location and the plant room, as well as the chimney and combustion air supply, also need to be clarified.
  3. Have the chimney checked. We check free of charge whether your chimney is suitable for the LUVANO®.
  4. Involve the chimney sweep. Involve your district chimney sweep at an early stage. They assess the room, chimney, combustion air supply and flue gas routing and later approve the system.
  5. Plan. We give you planning advice on positioning, buffer tank and hydraulic integration and coordinate with your heating installer. If you do not yet have a heating installer, we will name one near you.
  6. Install. Your heating installer sets up the LUVANO® and integrates it into the heating system. Your chimney sweep then approves the system.
  7. Commission. If needed or on request, our factory customer service takes care of commissioning: they adjust the stove, programme the control and show you how to operate it.

Output and version

This is not just about the maximum heating load on very cold days. Also decisive is how the heat demand is distributed over the entire heating season. In many buildings, full heat output is needed on only a few days a year. For large parts of the heating season, a significantly lower output is sufficient.

We offer the LUVANO® in different versions. Which variant makes sense depends on the desired ease of operation, the chimney situation and the planned heating concept.

LUVANO® BASIC

The LUVANO® BASIC is the pared-down version without electronic control technology. It is suitable for projects where a simple, robust and deliberately purist solution is wanted.

LUVANO® TOUCH

The LUVANO® TOUCH is our convenient variant with integrated control technology. The control takes over central functions of stove operation and regulates, among other things, the pump belonging to the LUVANO® and the integrated air supply flap.

Important temperatures and operating states can be displayed clearly on the touch display. This makes operation more convenient, more transparent and better matched to the heating system.

LUVANO® TOUCH PLUS

The LUVANO® TOUCH PLUS also has a fan kit to support the chimney draught. This variant is not necessary in every project. We recommend it only if a chimney calculation shows that additional support is sensible or necessary.

Our recommendation: For most systems, the LUVANO® TOUCH is the right solution, because it combines ease of operation, control technology and integration into the heating system very well.

Chimney

The chimney is crucial for operating a wood stove. Especially with boiler stoves, the chimney system should not just be roughly estimated but checked by calculation. We check free of charge before you buy whether your chimney is suitable. There are two forms for this: one for a chimney with a single appliance and one for a shared flue.

  • Draught requirement of the LUVANO®: 12Pa at 8kW, 15Pa at 10 and 15kW. The calculation shows whether your chimney achieves this draught.
  • Flue gas connection: 150mm; the cross-section must not be reduced further along.
  • Guide values: In many cases, a chimney with a length from 5m, ideally from 6m, and a diameter of 150 to 180mm is suitable. Avoid bends and long horizontal flue pipe runs: as a rule of thumb, each additional bend requires around one metre more chimney height. Only the calculation is reliable.
  • A shared flue is also possible in principle. The prerequisite is that the connected appliances are approved for this and the technical suitability is confirmed by a chimney calculation.
  • If the draught is insufficient, a fan kit supports the chimney draught: the LUVANO® TOUCH PLUS has it ex works, it can be retrofitted to the TOUCH, but not to the BASIC.
  • In a new build, it is best to plan the chimney in from the start. We can supply the chimney system and flue pipes on request.

→ Which chimney?

Installation

  • Dimensions: H 1,325 × W 550 × D 550mm, 1,370mm high with flue pipe; on this footprint the LUVANO® offers a fuel chamber of 25 litres. Weight approx. 320kg, just under 400kg with water.
  • Connection to the rear or downwards: depending on the version, water, power and air supply lines run through the wall or through the floor slab. For the downward connection there is a hydraulic connection set of around 70cm for the passage through the floor.
  • In a corner: the LUVANO® can also be installed at a 45° angle. In this case, check beforehand whether it remains easily accessible there. If there is no space behind the stove for the air supply line, the air supply connection can be moved inside; it then points vertically downwards inside the stove.
  • Air supply from outside: in modern or renovated buildings with an airtight building envelope, we often recommend a direct combustion air supply from outside. For this, the LUVANO® has a 120mm connector. It is available in a room-sealed version in accordance with EN 16510. This mode of operation includes the combustion air supply from outside; if a ventilation system is present, it is mandatory. → Room-sealed Your chimney sweep can tell you whether this version is an option for your house.
  • Delivery and moving into place: the LUVANO® is delivered by freight forwarder, fully assembled on a pallet of 75 × 75cm, and unloaded at ground level. You or your heating installer take care of transport to the installation site with a pallet truck; you provide any necessary lifting or transport aids on site. We will be glad to advise you on this.
Flue gasalways at the top Water, electricityand airto the rear Rear connection The pipes exit the stove at the rearand continue behind it. Flue gasalways at the top Water, electricityand airdownwards Bottom connection The pipes run directly through the floor,the rear panel remains closed. WaterElectricityAir
Water, electricity and air are connected at the rear or bottom, the flue gas always at the top into the chimney. Depending on the variant, the pipes run behind the stove or through the floor.

Buffer tank

The LUVANO® is always operated with a buffer tank: it transfers up to 85% of its output to the heating water, and the tank takes up this heat and makes it available when you need it. On many of the around 220 heating days a year, the stove supplies more than the house needs at that moment. The surplus charges the buffer tank and supplies radiators, underfloor heating and hot water even after the burn. If the stored heat is not sufficient, your second heat source switches on automatically and as needed.

We recommend a buffer volume of at least 500 litres for the LUVANO®. In many cases, 800 to 1,000 litres is the better solution. A larger buffer tank increases comfort, extends usable heating phases and improves the ways the stove can be used. We will work out with you before you buy which size makes sense for your house.

500lat least 800–1.000lideally
At least 500 litres, ideally 800 to 1,000 litres – a larger tank extends the usable heating phases.

On request, we supply the buffer tank with matching accessories, in three designs:

  • LUUMA system tank for heating and hot water – with fresh water station; further heat sources can be connected to it, such as a heat pump, pellet boiler, oil or gas boiler and solar thermal.
  • Buffer tank with stratification device – on request with fresh water station for hot water preparation.
  • Hygienic combination tank – with drinking water heating via a stainless steel heat exchanger, on request with a solar heat exchanger.

Hot water preparation via a fresh water module or via an integrated stainless steel heat exchanger is often particularly hygienic and space-saving.

Do you already have a tank? We integrate an existing buffer tank if this makes technical sense. An existing hot water cylinder can possibly also continue to be used, if its condition and integration allow.

Integration

Technically, the LUVANO® is a boiler and is integrated as such: it charges the buffer tank via a pump and thermal valve. The second heat source, the hot water preparation and the heating circuits are connected to the tank. The LUVANO® is never connected directly to the radiators, but always via the buffer tank.

  • Return temperature control: it keeps the return temperature to the LUVANO® above 60°C. Functioning return temperature control is a prerequisite for the five-year warranty on the boiler body; a two-year warranty applies to other delivered parts. → Warranty
  • Hydraulic package: return temperature control, expansion vessel (12l), cap valve and microbubble separator – matched to the LUVANO®.
  • Four lines: flow and return to the buffer tank and two lines for the thermal discharge safety device. It protects the stove against overheating, for example if the pump fails. For this, the built-in safety heat exchanger is connected to the cold water line.
  • Where the technology goes: return temperature control, pump, safety group and shut-off valves do not have to be mounted directly on the stove; they can also be accommodated in the boiler room or plant room.
  • Second heat source: a boiler stove built like a boiler, such as the LUVANO®, can provide a great deal of heating energy. Nevertheless, an additional heat source makes sense for most projects. It ensures the heat supply when you are not heating with wood, and covers peak loads on particularly cold days as well as summer operation. Options include a heat pump, a pellet boiler, the existing oil or gas boiler, an immersion heater or solar thermal. As long as your LUVANO® is in operation or the buffer tank is charged, the TOUCH control blocks the second heat source; you set the conditions for this yourself. If you deliberately want to heat with wood only, you block it at the press of a button.
  • Connections: flow and return ¾″ male thread, flue 150mm, air supply 120mm.
  • Power: TOUCH and TOUCH PLUS require a 230 V / 50 Hz connection; a 7m display cable is included.
additional heat source, e.g. oil or gas boiler Hot water heating Heating circuit (radiators) Pump Pump Buffer tank Thermostatic valve Mixing valve
Hydraulic diagram: the LUVANO® on the buffer tank, next to it the second heat source. Schematic diagram. Different hydraulic arrangements are available depending on requirements.

What is included

Important accessories are included in the scope of delivery: the thermal discharge safety device for the internal safety heat exchanger, the connection set, poker, cleaning brush and glove.

On request, we supply everything from a single source: buffer tank (also with drinking water heating), hydraulics and pump groups, control technology, chimney system and flue pipes, heat pump or pellet boiler – matched to each other for clean planning and integration.

After installation

Behind the LUVANO® is LUUMA, the manufacturer from Büchenbach in Franconia. Even after commissioning, our factory customer service is available to you and your heating installer – in person and by phone. You can find customer service and spare parts at luuma-energy.de.

Frequently asked questions

Can I connect the LUVANO® directly to the radiators?

No, the connection is always made via a buffer tank. The LUVANO® charges the tank; radiators, underfloor heating and hot water preparation draw the heat from it – even after the burn.

How big does the buffer tank need to be?

At least 500 litres, ideally 800 to 1,000 litres. We will determine the right size for your house together with you.

Do I have to buy the tank and hydraulics from LUUMA?

No. Your heating installer can also integrate tanks and hydraulics from other manufacturers. The prerequisites are a sufficiently large buffer tank and functioning return temperature control. On request, we supply everything from a single source.

Who installs the LUVANO®?

Your heating installer. If you do not have one yet, we can name one near you. If necessary or on request, our factory customer service takes care of commissioning.

Is my chimney suitable?

We check this free of charge before you decide. You will receive the form for this with the information pack. Also involve your district chimney sweep at an early stage.