LUVANO

What does room-sealed mean for a wood stove?

The combustion air comes from outside, not from the room where the stove is installed.

A room-sealed wood stove draws its combustion air from outside via its own duct. It is built so that it does not take any air from the room in which it is installed. This matters in buildings with an airtight envelope, especially those with a ventilation system or cooker hood. If you take this into account early on, you can coordinate the appliance, ventilation system and kitchen with each other from the outset.

Ventilation system, cooker hood, wood stove: where does the air come from?

Imagine you are planning a new build and have three plans in front of you. The first shows the mechanical ventilation. On the second, a cooker hood in extraction mode is drawn in the kitchen, which conveys the kitchen air outside. On the third, the wood stove stands in the living room. Each of these plans is coherent in itself. Together, however, they raise a question that none of them answers: where does the air come from?

In an older building, it flows in by itself through joints and cracks in the building envelope. In a new build, precisely this is no longer intended: the Gebäudemodernisierungsgesetz (German Building Modernisation Act) requires the building envelope to be sealed “permanently airtight, including the joints”. The same section, however, makes clear that the regulations on the “minimum air exchange required for the purposes of health and heating” remain unaffected. Energy-saving law therefore requires an airtight building envelope and, for the air that occupants and heating need, refers to other regulations. For the combustion appliance, these are the Feuerungsverordnungen (firing ordinances) of the federal states.

If the ventilation system and cooker hood extract air from an airtight building, this air has to flow in elsewhere. If too little flows in, negative pressure develops in the room. An appliance that takes its combustion air from the room where it is installed then competes with the hood for the same air. In the worst case, flue gas could enter the room instead of the chimney.

The Feuerungsverordnungen of the federal states regulate precisely this case. In Bavaria, it says: “The operational safety of room-air-dependent combustion appliances must not be impaired by the operation of systems that extract room air, such as ventilation or warm-air heating systems, cooker hoods, exhaust air tumble dryers.”

What this actually says: the regulation thinks not in terms of appliances but in terms of air. Ventilation systems, cooker hoods and exhaust air tumble dryers are all the same to it – systems that extract air from the building. None of them is prohibited, nor is the combustion appliance. What is required is that they do not work against each other. This is fulfilled, for example, if a safety device prevents the combustion appliance and the extracting system from operating at the same time. It is equally sufficient if it is technically ensured that no dangerous negative pressure can arise while the combustion appliance is in operation.

A room-sealed stove draws its combustion air from outside via its own duct, not from the room where it is installed. However, this does not settle anything for the cooker hood: legally, it remains a separate question, even with a room-sealed stove. In practice, a safety device is required for this, for example a window contact switch that only allows the hood to operate when the window is open.

For the three plans, this means: coordinate them with each other early on, and involve your chimney sweep, who checks whether the combustion appliance and ventilation system can be operated safely together. What applies in the individual case, what is possible and what is permitted is ultimately decided by the responsible chimney sweep.

→ Which chimney?

Air supplyfrom outside Flue gas Cooker hood Windowcontact Negative pressure
The LUVANO® draws its combustion air from outside through its own duct. A cooker hood in extraction mode nevertheless requires a safety device, such as a window contact.

What “room-sealed” means exactly

A room-air-dependent stove takes its combustion air from the room where it is installed. For this, enough air must be able to flow in. Decisive factors include room size, air connection between rooms, building envelope and other ventilation equipment.

For the counterpart, the Feuerungsverordnung (German Firing Systems Ordinance) contains a precise definition: room-sealed appliances are those “to which combustion air is supplied through ducts or shafts only directly from the open air and from which no flue gas can escape into the room where they are installed in dangerous quantities”. Other appliances are room-air-dependent.

What this actually says: a duct to the outside alone does not make a stove room-sealed. It must also be of airtight construction, above all at the firebox and doors: it must not draw in air from the room where it is installed, and no flue gas may escape into that room in dangerous quantities. Being room-sealed is therefore above all a property of the design. For wood stoves, the European standard EN 16510 now contains specifications on this.

With a ventilation system: air supply from outside

If a ventilation system is present, the air supply from outside can be mandatory – it is part of room-sealed operation in accordance with EN 16510. In addition, the ventilation system must not create dangerous negative pressure in the room where the stove is installed. The chimney sweeps’ trade guidance sheet sets 8 pascals for this for room-sealed appliances. How the appliance and the ventilation system interact is checked on a case-by-case basis.

The LUVANO® boiler stove in the room-sealed version

The LUVANO® wood-burning boiler stove is available in a room-sealed version in accordance with EN 16510 – previously already approved by the DIBt (German Institute for Building Technology). The combustion air is supplied from outside through a separate connection with a diameter of 120mm. Your chimney sweep can tell you whether this version is suitable for your building.

If the stove is installed in a corner, the air supply connection can be moved inside: it then points vertically downwards inside the stove, and the combustion air continues to come from outside.

→ Installation and air supply · The LUVANO® in a new build

Frequently asked questions

Do I need a room-sealed wood stove in a new build?

For modern or renovated buildings with an airtight building envelope, we often recommend a direct combustion air supply from outside. What applies in your case is clarified by the planner and chimney sweep.

What is EN 16510?

The European standard for residential solid fuel burning appliances. The LUVANO® is available in a room-sealed version in accordance with this standard.

Wood stove and cooker hood – what do you need to consider?

A cooker hood in recirculation mode does not extract any air from the building. If it works in extraction mode, a safety device is required, such as a window contact switch that only enables the hood when the window is open. This also applies to a room-sealed wood stove.

Sources5 references – click to expand
  • Feuerungsverordnung (FeuV) Bayern (Bavarian Firing Systems Ordinance) of 11 November 2007, § 2 para. 2, § 3 and § 4 para. 2 – gesetze-bayern.de
  • Bundesverband des Schornsteinfegerhandwerks – Zentralinnungsverband (ZIV, German chimney sweeps' federation): “Merkblatt für den gemeinsamen Betrieb von Feuerstätten für feste Brennstoffe, Lüftungsgeräten und Luft absaugenden Einrichtungen”, reg. no. 2.5.2.24, May 2017 – energie-wuerzburg.de (copy)
  • Act on Saving Energy and Modernising Heat Supply in Buildings (Gebäudemodernisierungsgesetz – GModG), § 13 Airtightness – gesetze-im-internet.de
  • DIN EN 16510-1:2023-02, Häusliche Feuerstätten für feste Brennstoffe – Teil 1: Allgemeine Anforderungen und Prüfverfahren (Residential solid fuel burning appliances – Part 1: General requirements and test methods) (German version EN 16510-1:2022) – dinmedia.de
  • LUUMA ENERGY GmbH: manufacturer's information on the LUVANO®