LUVANO

What is a boiler stove?

A wood stove that heats not only the room where it is installed but also the heating water.

A wood-burning boiler stove fulfils two tasks: it heats the room in which it stands and at the same time transfers heat to the heating water. Via the buffer tank, this heat reaches the other rooms – and is still available long after the fire has gone out.

LUVANO®Buffer tankRadiatorsUnderfloor heatingHot water
First into the buffer tank, then into distribution: the tank keeps the heat ready for radiators, underfloor heating and hot water.

Fire in the evening, hot water in the morning

Imagine an evening in October: around 6 pm you light the fire, add wood once or twice, and by around 10 pm it has burned down. The living room has been pleasantly warm all evening – and that is all you expected of this fire.

Unnoticed, however, more has happened during these hours. Heating water has flowed through the stove, and a pump has carried the heat into the buffer tank – a large, well-insulated water tank in the plant room. There the water stratifies according to its temperature: the hot water at the top, the cooler water below.

The next morning, the fire has been out for hours. The heat for the shower and for the radiators nevertheless comes from the buffer tank.

This is the real difference from a conventional wood stove – not that water flows through the stove, but that the heat is stored. The buffer tank shifts it in time: from the evening, when you like to light a fire, to the morning, when you need hot water.

The buffer tank is necessary for a simple reason: a wood fire cannot be switched off like an oil or gas burner. The fuel that has been loaded burns down, and the heat released has to be carried away. On mild days, when the radiators take up hardly any heat, the buffer tank absorbs it; without it, the stove would overheat.

How much heat you can store is determined by the ratio between the heat demand of your house and the water output of the stove. If the heat demand on cold days exceeds the output of the stove, the heat generated is used immediately – the buffer tank is not charged. On many of the around 220 heating days a year, however, the stove supplies more than the house needs at that moment: whether you run it during the day, only in the evening or in the morning and evening, the surplus charges the buffer tank, and your house is supplied from this reserve for hours. If it is not sufficient, your second heat source – heat pump, pellet boiler, oil or gas heating – switches on automatically and as needed.

The same ratio determines the size of the buffer tank. If the heat demand of your house is close to the water output of the stove, a large part of the heat is used immediately, and a smaller tank of around 500 litres is usually sufficient. If the heat demand is significantly lower, the tank has to take up the surplus. This applies in a well-insulated house as well as in the long transitional season, which often begins in the bathroom as early as September and lasts into May. Then 800 to 1,000 litres makes sense. For the LUVANO®, we recommend at least 500 litres, ideally 800 to 1,000 litres.

A larger buffer tank offers a further advantage: it can also heat the drinking water – on the instantaneous principle, either via a stainless steel corrugated pipe in the tank or via a fresh water station. The drinking water is only heated at the moment you draw it. (An existing hot water cylinder can also remain connected.) As no heated drinking water is stored on the instantaneous principle, the risk of legionella growth falls. It is not ruled out: sufficiently high temperatures and short pipe runs remain decisive, and the drinking water reaches at most the temperature the buffer tank currently has.

evening Tankcharging morning HotWater Fire out
In the evening the fire charges the buffer tank. In the morning it has gone out – the heat for the shower comes from the tank.

What the law understands by a wood stove

The EU Ecodesign Regulation determines what a wood stove is. It calls it a “solid fuel local space heater”: a device that emits heat “by direct heat transfer or by direct heat transfer in combination with heat transfer to a fluid, in order to reach and maintain a certain level of human thermal comfort within an enclosed space in which the product is situated, possibly combined with a heat output to other spaces”.

What this actually says: the law thinks of the wood stove from the room where it is installed. Its purpose is the room in which it stands; the other rooms only appear in a subordinate clause – heat can also reach them. In your house, the “fluid” is the heating water. A boiler stove is therefore a wood stove that takes this subordinate clause seriously. (To what extent, however, varies enormously. Boiler stoves are worlds apart – in the share of heat that goes into the heating water, as well as in design, fuel chamber and durability. It is no different with cars: a small car is a car, and so is a family estate – and yet the two are built for very different tasks.)

The regulation also distinguishes where the heat goes: what the stove releases to the room where it is installed through radiation and convection is the direct heat output; what it releases to the water is the indirect heat output. The manufacturer must state both values in the operating instructions and on its website. At the same time, the regulation draws a line: if an appliance releases less than 6% of its heat directly to the room at nominal heat output, it is no longer covered by these rules. Legally, therefore, a wood stove always includes heat for the room where it is installed – to what extent is a question of design.

With central heating, the fire once moved from the living room to the cellar: a boiler heated the whole house, and the living spaces were given radiators. The boiler stove brings the fire back into the living space – without giving up radiators and underfloor heating.

What share goes into the heating water

This is determined by the design: the larger the water-contact surface in the stove, the higher the share that goes into the heating water. Some boiler stoves have a water jacket, others are built like a boiler. In the data sheet you will find both values, the heat output to the room and to the water. If you divide the water-side output by the total output, you get the share that benefits the whole house.

How much this share matters becomes clear on an evening in September: the bathroom needs heat, the living room hardly any. The lower the room output of your stove, the more readily you can heat even on such evenings – and the less often the living room gets too warm.

→ Replacing a boiler stove

From the simple wood stove to the boiler with a viewing window

What is rarely misunderstood is the principle; what is misunderstood is the difference between the designs. Many people think of a wood stove with a small water jacket, not of a boiler with a viewing window like the LUVANO®.

If you rank wood stoves by how much of their heat benefits the whole house, a clear gradation emerges. At one end are simple wood stoves without water connection – entry-level appliances that release their entire output to the room where they are installed and can store hardly any heat. Heat-storing stoves go one step further; their storage mass releases the heat over hours – but likewise only to the room in which they stand.

The boiler stove is the first to release part of its output to the heating water and thus to the whole house. With many appliances of this type, however, a considerable part of the output still remains in the room where it is installed. What always matters is the ratio of room output to total output. A worked example: if a stove with a total output of 12kW releases 8kW to the water, 4kW – a third – remains in the living room, even on a mild evening when this room needs hardly any heat.

At the other end of the scale is the boiler with a viewing window. It takes the principle to its logical conclusion: as much heat as possible into the heating water, as little as necessary into the room. Boiler does not mean less of a wood stove. It means a fully fledged wood stove with a visible fire – plus the advantages of a basement boiler: a high water output, a large fuel chamber with a long burn time, a robust, durable design and easy ash removal and cleaning. The LUVANO® is such a boiler with a viewing window: up to 85% of its output goes into the heating water, only just under 15% into the room where it is installed.

The further to the right a stove sits on this scale, the more you gain. A wood stove stays in the living room all year round, even in summer. All the more worthwhile, then, if during the heating season it releases as large a part of its heat as possible to where the house needs it – to the heating water. A very high water output with very low room output extends the usable heating period of the stove: you can also run it in the transitional season, from September into May. This significantly increases your independence, lowers heating costs – especially if you can get wood cheaply – and at the same time takes the load off your second heat source.

→ Replacing a wood stove · Can a wood stove replace your heating?

Intermittent or continuous burning

How much wood can be loaded at once is not just a question of convenience – the law also makes a distinction on this basis. The Ordinance on Small and Medium Combustion Plants (1. BImSchV) recognises two types of room heater: the “room heater with flat firing”, tested as “intermittent burning” (Zeitbrand), and the “room heater with fill firing”, tested as “continuous burning” (Dauerbrand). The same dust limits apply to both; for efficiency, the ordinance requires at least 73% for intermittent burning and at least 70% for continuous burning.

What this actually says: the ordinance does not distinguish by daily operating time, but by the amount of fuel per load. In flat firing, only one layer of logs is loaded each time wood is added, usually two to five kilograms. Fill firing takes more fuel and accordingly burns longer on one load.

Continuous burning is therefore a mode of operation and not a mark of quality, even though this is often assumed. The ordinance even permits a slightly lower efficiency for continuous burning than for intermittent burning. And when heating with wood, continuous burning does not mean that the stove burns right through the night: according to the test standard, one load must last at least 45 minutes in an intermittent-burning stove and at least 90 minutes in a continuous-burning stove for wood.

The LUVANO® is tested as continuous burning. More meaningful for everyday use, however, is the burn time: its fuel chamber holds 25 litres, and one load burns for over three hours. If you do not want to keep adding wood, you should therefore look at burn time and fuel chamber size when comparing – not at the label “continuous burning”.

How the stove is integrated into the heating

A boiler stove is integrated into the heating system like a boiler: flow and return lead to the buffer tank, and a pump provides circulation. In addition, there are two devices that every heating engineer knows from the boiler in the boiler room.

The first is the thermal discharge safety device. If, for example, the pump fails while the fire is burning, heat is no longer drawn from the stove – but the wood continues to burn. At around 95°C a valve then opens: cold mains water flows through a safety heat exchanger in the stove, cools it and drains into the waste water connection. The standard for heating systems, DIN EN 12828, requires this emergency cooling for heat sources whose firing cannot be switched off quickly; boiler stoves without a thermal discharge safety device therefore exist only in exceptional cases.

What this actually says: what matters is not the size of the stove, but that its fire keeps burning until the wood is used up – with any wood firing, including the boiler in the cellar. The discharge safety device needs a cold water connection that cannot be shut off and should be checked once a year to make sure it works. With the LUVANO®, it is included in the scope of delivery.

The second is return temperature control, also called return temperature boosting. When lighting up, the stove is cold. The hot flue gases meet cold boiler walls, and the water vapour in the flue gas condenses – the same effect as a bottle from the fridge misting up in warm air. This condensate is acidic and, over time, attacks even high-quality boiler steel. This applies to any biomass firing, whether boiler or wood stove.

That is why a valve is installed in the return. As long as the water from the stove is cooler than around 60°C, it circulates in a small loop around the stove, which therefore quickly reaches its operating temperature. Only above that does the valve open and mix in cooler water from the buffer tank. Then, for example, 70°C flows into the tank and 60°C back into the stove. With a wood stove, a thermally controlled valve is usually sufficient for this. For the LUVANO®, functioning return temperature control above 60°C is also a prerequisite for the five-year warranty on the boiler body.

(If you have already integrated a log or pellet boiler, you can also integrate a boiler stove: the hydraulic principle is the same – only the appliance stands in the living space instead of the boiler room.)

The same requirements for the chimney and combustion air apply as for any wood stove. If a further stove is to be connected to the same chimney (shared flue), the appliances must be suitable for this, and a calculation must prove that the flue gases are safely discharged in every operating state. No flue gas may escape through a fireplace that is not in operation at the time. Before commissioning, the authorised district chimney sweep certifies that the system is safe to use. In houses with a ventilation system, the stove must draw its combustion air from outside. → Which chimney? → Room-sealed

What to look for when comparing

A boiler stove is a purchase for many years, so do not compare nominal output alone. Meaningful indicators are the size of the fuel chamber and the permissible log length, the burn time and the efficiency. Equally important are a durable design and the effort required for cleaning and ash removal, including the accessibility of the cleaning openings. Also check whether smoke escapes into the room when adding wood and how the output is distributed between water and room. Finally, the output you need determines how much wood you use. → How does a wood gasification stove work?

Who it is suitable for

A boiler stove is a heating system and not just a living-room fire. In the right design, it can significantly take the load off the existing heating system. It is suitable for anyone who likes heating with wood and wants to use the heat of the fire throughout the house – as a supplement to a heat pump, pellet boiler, oil or gas heating, in existing buildings as well as new builds. (If you are planning a wood stove in the living room anyway, you might as well do it properly.) If you are mainly looking for a fire to look at, you are better off with a conventional wood stove.

The LUVANO®: a boiler stove built like a boiler

The LUVANO® is not a wood stove with a water jacket, but a boiler with a viewing window. It was developed from the SH series log boiler – from a technology that has matured in the boiler room over decades. Such a boiler is designed from the ground up to transfer a high share of its heat to the heating water and to burn for a long time on one load. Its boiler body is double-walled and surrounded by water on all sides, at the top and bottom and right up between the doors. The panes made of ROBAX® Energy-Max glass also hold back heat radiation. This design results in the ratio of up to 85% water output to just under 15% room output.

What the LUVANO® makes possible is shown by our customers' feedback: some supplement their heating with 5 stacked cubic metres of wood a year, others with 15 and more. How much heat you obtain from wood is up to you.

This is how much energy is in wood

5 stacked cubic metresmixed wood · around 8,000kWh
800 litresheating oil

Almost as much as a newly built house with 150m² of living space needs in heating energy for the whole year (around 9,000kWh).

15 stacked cubic metresmixed wood · around 24,000kWh
2,400 litresheating oil

More than an older single-family house uses in heating energy per year (around 20,000kWh).

1 stacked cubic metre of mixed wood, half beech and half spruce, air-dried: around 1,600kWh. Sources: Bayerische Landesanstalt für Wald und Forstwirtschaft (Bavarian State Institute of Forestry), Merkblatt 12 (information sheet 12) (2024); Verbraucherzentrale (2026).

With the LUVANO® TOUCH, an air flap regulates the combustion air based on the flue gas temperature. If the chimney draught changes, the flue gas temperature changes too – and the control responds to it. When the wood has burned out, the flap closes and interrupts the chimney draught: the heat generated remains in the stove and in the buffer tank instead of being lost through the chimney. The fuel chamber holds 25 litres, and one load burns for over three hours.

→ More about the LUVANO®

The LUVANO® from behind: surrounded by water on all sides, right up between the doors.
The LUVANO® from behind: surrounded by water on all sides, right up between the doors.

Frequently asked questions

Does a boiler stove need electricity?

For the circulation pump that carries the heating water to the buffer tank, yes; with the LUVANO® TOUCH also for the control (230 V). For a power cut, there is a simple solution for the LUVANO® – talk to us.

Is it possible without a buffer tank?

The LUVANO® is always operated with a buffer tank. Without a tank, the heating system would have to take up the heat exactly when the fire is burning; with a tank, you use it when you need it. → Buffer tank

Can my heating engineer integrate a boiler stove?

Yes. They integrate it like a boiler – with a buffer tank, pump, return temperature control and thermal discharge safety device.

Is a boiler stove eligible for funding?

The stove itself is not; a shared buffer tank may be under certain circumstances. → Funding

Sources12 references – click to expand
  • Bayerische Landesanstalt für Wald und Forstwirtschaft (LWF, Bavarian State Institute of Forestry): information sheet 12 “Der Energieinhalt von Holz”, November 2024, pp. 1 and 3 – lwf.bayern.de
  • Verbraucherzentrale: “So viel teurer macht der CO₂-Preis Ihre Heizkosten”, as of 06.01.2026 – verbraucherzentrale.de
  • Commission Regulation (EU) 2015/1185 of 24 April 2015 (ecodesign requirements for solid fuel local space heaters), Art. 1(2)(c), Art. 2 points 1, 16 and 17, Annex II – eur-lex.europa.eu
  • Umweltbundesamt (German Environment Agency): data sheet “Festbrennstoff-Einzelraumheizgeräte – Ökodesign-Richtlinie und Energieverbrauchskennzeichnung”, as of March 2018 – umweltbundesamt.de
  • Erste Verordnung zur Durchführung des Bundes-Immissionsschutzgesetzes (1. BImSchV, German Ordinance on Small and Medium Combustion Plants), Annex 4 No. 1 – gesetze-im-internet.de
  • Fachagentur Nachwachsende Rohstoffe / Technologie- und Förderzentrum (German Agency for Renewable Resources / Technology and Support Centre): Handbuch Bioenergie-Kleinanlagen, 3rd edition 2013, chap. 6.1.2 and 6.1.4.1 – tfz.bayern.de
  • HKI Industrieverband Haus-, Heiz- und Küchentechnik (German trade association for home, heating and kitchen technology): press release “Wärmstens zu empfehlen – Holzöfen im Überblick”, 13.09.2022 – hki-online.de
  • SBZ Monteur 06/2012: article on integrating boiler stoves (thermal discharge safety device in accordance with DIN EN 12828) – sbz-monteur.de
  • Bayerische Feuerungsverordnung (FeuV, Bavarian Firing Ordinance), § 7(4) – gesetze-bayern.de; Bayerische Bauordnung (Bavarian Building Code), Art. 78(3) – gesetze-bayern.de
  • Umweltbundesamt: “Trinkwarmwasserkonzepte für Gebäude mit einer Wärmepumpenheizung”, as of 01.11.2023, section 3.2.3 and table 1 – umweltbundesamt.de
  • DVGW (German Technical and Scientific Association for Gas and Water): “Energieeinsparungen im Warmwasserbereich”, March 2023 – dvgw.de
  • LUUMA ENERGY GmbH: manufacturer's information on the LUVANO®